{"id":14790,"date":"2026-09-14T20:48:25","date_gmt":"2026-09-14T20:48:25","guid":{"rendered":"https:\/\/www.jstconsultancy.cz\/?p=14790"},"modified":"2026-09-14T20:56:18","modified_gmt":"2026-09-14T20:56:18","slug":"metalco-and-astm-e3499-25","status":"publish","type":"post","link":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/","title":{"rendered":"Metalco and ASTM E3499-25"},"content":{"rendered":"<p>Last week, I visited<strong> V\u0160B-TUO<\/strong>. One reason was my work within the <strong>NCK<\/strong> (National Competence Centre), but since I knew <strong>Metalco<\/strong> was hosting a presentation there on new laboratory instrumentation, I combined the two trips.<\/p>\n<p>So, what did I learn? New equipment was unveiled that evaluates mechanical properties using indentation plastometry based on profilometry <strong>(PIP)<\/strong>. This method is now covered by standards such as A<strong>STM E3499-25<\/strong> (Standard Test Method for Indentation Plastometry of Metallic Materials) and <strong>DIN SPEC 4864:2019-11<\/strong> (Test method for the determination of flow curves and benchmark characteristic values \u200b\u200bfor tensile testing by means of minor destructive indentation, <strong>3D measurement,<\/strong> and finite-element material models).<\/p>\n<p>What is it exactly? The principle of indentation combined with inverse <strong>FEM<\/strong> analysis has been a subject of research for years\u2014including at the University of Cambridge. In parallel,<strong> IMPrintec<\/strong> developed its i3D technology, which was standardized in 2019 via <strong>DIN SPEC 4864<\/strong>. Methodologically, it is a physical approach that extracts stress-strain curves\u2014including yield strength and tensile strength\u2014from indentation test data using an inverse finite element method. It sounds mysterious. Unlike conventional hardness testing, local mechanical characteristics comparable to tensile test results are derived from the 3D geometry of the indentation and an inverse <strong>FEM<\/strong> model. Simply put:<\/p>\n<p><strong>The indenter is pressed into the material \u2192 the 3D shape of the indentation is measured \u2192 FEM simulates the indentation \u2192 software adjusts material parameters until the simulated indentation matches the actual one \u2192 the tensile \u03c3\u2013\u03b5 curve is derived from this.<\/strong><\/p>\n<p>And why <strong>FEM<\/strong>\u2014specifically, the inverse finite element method? Normally, we know the material properties and use <strong>FEM<\/strong> to calculate the deformation. Here, it is the other way around: we know the deformation and seek the material properties that caused it. To quote a classic phrase, it\u2019s a &#8222;neat trick.&#8220;<\/p>\n<p>The measurement process requires relatively little surface preparation compared to fabricating a standard tensile test specimen, which reduces turnaround time and costs. And the accuracy? <strong>IMPrintec<\/strong> cites a figure of 3.6%.<\/p>\n<p>What does the device look like?<strong> IMPrintec<\/strong> manufactures it in several variants. However, the <strong>i3D\u00aemBV<\/strong> version also combines HV and HB hardness testing with profilometry.<\/p>\n<p><a href=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-14781\" src=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-300x106.png\" alt=\"\" width=\"637\" height=\"225\" srcset=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-300x106.png 300w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-1024x360.png 1024w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-768x270.png 768w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-1536x540.png 1536w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-260x91.png 260w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-50x18.png 50w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-150x53.png 150w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-1920x682.png 1920w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314-500x176.png 500w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-203314.png 1939w\" sizes=\"auto, (max-width:767px) 480px, 637px\" \/><\/a><a href=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-14783\" src=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-300x225.jpg 300w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-1024x768.jpg 1024w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-768x576.jpg 768w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-1536x1152.jpg 1536w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-195x146.jpg 195w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-50x38.jpg 50w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-100x75.jpg 100w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-960x720.jpg 960w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-250x188.jpg 250w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie-500x375.jpg 500w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/IMG_2952-kopie.jpg 2048w\" sizes=\"auto, (max-width:767px) 300px, 300px\" \/><\/a><\/p>\n<p>In this case, in addition to hardness, we obtain <strong>R<sub>p0.2<\/sub> <\/strong>(the offset yield strength), <strong>R<sub>m<\/sub><\/strong> (tensile strength), and the plastic region of the stress-strain curve. While conventional tensile testing involves measurements on a sample separate from the actual component, this method allows for measurement directly on the part of interest. The method cannot determine the fracture characteristics associated with conventional tensile testing\u2014specifically, elongation at break <strong>(A)<\/strong> and reduction of area <strong>(Z)<\/strong>. However, <strong>ASTM E3499<\/strong> does allow for the derivation of uniform elongation (prior to necking). Furthermore, the method cannot be applied if the grain size exceeds one-third of the indentation diameter.<\/p>\n<p><a href=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-14785\" src=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842-300x144.png\" alt=\"\" width=\"300\" height=\"144\" srcset=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842-300x144.png 300w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842-1024x493.png 1024w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842-768x369.png 768w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842-260x125.png 260w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842-50x24.png 50w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842-150x72.png 150w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842-500x241.png 500w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-205842.png 1083w\" sizes=\"auto, (max-width:767px) 300px, 300px\" \/><\/a><\/p>\n<p>As for applications? Analysis of <strong>EBW\/LBW\/TIG<\/strong> welds and the heat-affected zone <strong>(HAZ)<\/strong>, comparison of heat treatment effects, local heterogeneity in large forgings, <strong>AM Ti6Al4V\/IN718<\/strong>, property mapping in AM parts, failure analysis, inspection of actual components from which standard tensile specimens cannot be machined, and optimization of quenching and tempering parameters.<\/p>\n<p>The method is not recommended for cast iron, materials with strong texture, highly anisotropic AM materials, very coarse-grained materials, or gradient layers where the plastic zone spans multiple distinct microstructures. This is due, in part, to the FEM model&#8217;s assumption that plastic behavior in tension and compression is approximately symmetrical.<\/p>\n<p>The economic aspect is also compelling. According to calculations presented by the manufacturer, the cost per measurement point can be approximately five times lower than that of a conventional tensile test.<\/p>\n<p><a href=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-scaled.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-14787\" src=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-300x122.png\" alt=\"\" width=\"300\" height=\"122\" srcset=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-300x122.png 300w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-1024x417.png 1024w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-768x313.png 768w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-1536x626.png 1536w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-scaled.png 2048w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-260x106.png 260w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-50x20.png 50w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-150x61.png 150w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/Snimek-obrazovky-2026-09-14-200552-500x204.png 500w\" sizes=\"auto, (max-width:767px) 300px, 300px\" \/><\/a><\/p>\n<p>And its applications? They are numerous, though it is not suitable where a tensile test according to <strong>EN ISO 6892<\/strong> is mandatory. However, it is ideal for incoming material inspection, for situations requiring periodic measurements where producing numerous samples is either undesirable or too costly, and\u2014thanks to the availability of portable devices\u2014for inspecting pipelines, large castings, and weldments, or for evaluating the results of stress-relief annealing on large welded structures.<\/p>\n<p>Indentation plastometry is not simply a miniature tensile test. It is a localized experimental measurement combined with the mathematical identification of a material model, from which characteristics comparable to those of a tensile test are derived.<\/p>\n<p>Metalco has once again impressed by targeting the right market segment. Congratulations\u2014this really caught my interest.<\/p>\n<p>=======================================================================================================<br \/>\n<strong>Are you solving a similar problem? I will help you with the analysis\u2026<\/strong><br \/>\n<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"&#x2714;\" \/>\u00a040+ years of experience in the field<br \/>\n<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"&#x2714;\" \/>\u00a030+ years of experience\u2026 HT-PROGRES, Bodycote, Galvamet<br \/>\n<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"&#x2714;\" \/>\u00a0cooperation\u2026 V\u0160B, Czechimplant, ECM Technologies, TAV Vacuum Furnaces, GHC Invest<br \/>\n<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"&#x2714;\" \/>\u00a012+ years of expert activity<br \/>\nWant to ask for a solution or want a non-binding consultation? Click on this link, I will usually respond within 24 hours.\u00a0<a href=\"mailto:stanislav.jirka@gmail.com\">Contact email<\/a><br \/>\n========================================================================================================<br \/>\n<strong>Ji\u0159\u00ed Stanislav, Ing. CSc.<br \/>\n<\/strong>Consultant and forensic expert<br \/>\n========================================================================================================<\/p>\n<p>14\/9\/2026<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Last week, I visited V\u0160B-TUO. One reason was my work within the NCK (National Competence Centre), but since I knew Metalco was hosting a presentation there&#8230;<\/p>\n","protected":false},"author":12,"featured_media":14746,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[339,330],"tags":[],"class_list":["post-14790","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-heat-treatment-shop-equipment-en","category-quality-systems-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Metalco and ASTM E3499-25 - JST Consultancy<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/\" \/>\n<meta property=\"og:locale\" content=\"cs_CZ\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Metalco and ASTM E3499-25 - JST Consultancy\" \/>\n<meta property=\"og:description\" content=\"Last week, I visited V\u0160B-TUO. One reason was my work within the NCK (National Competence Centre), but since I knew Metalco was hosting a presentation there...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/\" \/>\n<meta property=\"og:site_name\" content=\"JST Consultancy\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-14T20:48:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-14T20:56:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/hp-kopie.png\" \/>\n\t<meta property=\"og:image:width\" content=\"650\" \/>\n\t<meta property=\"og:image:height\" content=\"138\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ji\u0159\u00ed Stanislav\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Napsal(a)\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ji\u0159\u00ed Stanislav\" \/>\n\t<meta name=\"twitter:label2\" content=\"Odhadovan\u00e1 doba \u010dten\u00ed\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/\"},\"author\":{\"name\":\"Ji\u0159\u00ed Stanislav\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#\\\/schema\\\/person\\\/7edfc0603f64b2f7bc0ba172e703fc76\"},\"headline\":\"Metalco and ASTM E3499-25\",\"datePublished\":\"2026-09-14T20:48:25+00:00\",\"dateModified\":\"2026-09-14T20:56:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/\"},\"wordCount\":792,\"image\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hp-kopie.png\",\"articleSection\":[\"Heat treatment shop equipment\",\"Quality systems\"],\"inLanguage\":\"cs\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/\",\"url\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/\",\"name\":\"Metalco and ASTM E3499-25 - JST Consultancy\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hp-kopie.png\",\"datePublished\":\"2026-09-14T20:48:25+00:00\",\"dateModified\":\"2026-09-14T20:56:18+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#\\\/schema\\\/person\\\/7edfc0603f64b2f7bc0ba172e703fc76\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/#breadcrumb\"},\"inLanguage\":\"cs\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hp-kopie.png\",\"contentUrl\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hp-kopie.png\",\"width\":650,\"height\":138},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/metalco-and-astm-e3499-25\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Metalco and ASTM E3499-25\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#website\",\"url\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/\",\"name\":\"JST Consultancy\",\"description\":\"Tepeln\u00e9 zpracov\u00e1n\u00ed kov\u016f, expertn\u00ed \u010dinnost, ekonomick\u00e9 anal\u00fdzy kal\u00edren, \u0161kolen\u00ed tepeln\u00e9ho zpracov\u00e1n\u00ed\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"cs\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#\\\/schema\\\/person\\\/7edfc0603f64b2f7bc0ba172e703fc76\",\"name\":\"Ji\u0159\u00ed Stanislav\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Metalco and ASTM E3499-25 - JST Consultancy","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/","og_locale":"cs_CZ","og_type":"article","og_title":"Metalco and ASTM E3499-25 - JST Consultancy","og_description":"Last week, I visited V\u0160B-TUO. One reason was my work within the NCK (National Competence Centre), but since I knew Metalco was hosting a presentation there...","og_url":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/","og_site_name":"JST Consultancy","article_published_time":"2026-09-14T20:48:25+00:00","article_modified_time":"2026-09-14T20:56:18+00:00","og_image":[{"width":650,"height":138,"url":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/hp-kopie.png","type":"image\/png"}],"author":"Ji\u0159\u00ed Stanislav","twitter_card":"summary_large_image","twitter_misc":{"Napsal(a)":"Ji\u0159\u00ed Stanislav","Odhadovan\u00e1 doba \u010dten\u00ed":"4 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/#article","isPartOf":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/"},"author":{"name":"Ji\u0159\u00ed Stanislav","@id":"https:\/\/www.jstconsultancy.cz\/#\/schema\/person\/7edfc0603f64b2f7bc0ba172e703fc76"},"headline":"Metalco and ASTM E3499-25","datePublished":"2026-09-14T20:48:25+00:00","dateModified":"2026-09-14T20:56:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/"},"wordCount":792,"image":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/hp-kopie.png","articleSection":["Heat treatment shop equipment","Quality systems"],"inLanguage":"cs"},{"@type":"WebPage","@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/","url":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/","name":"Metalco and ASTM E3499-25 - JST Consultancy","isPartOf":{"@id":"https:\/\/www.jstconsultancy.cz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/#primaryimage"},"image":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/hp-kopie.png","datePublished":"2026-09-14T20:48:25+00:00","dateModified":"2026-09-14T20:56:18+00:00","author":{"@id":"https:\/\/www.jstconsultancy.cz\/#\/schema\/person\/7edfc0603f64b2f7bc0ba172e703fc76"},"breadcrumb":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/#breadcrumb"},"inLanguage":"cs","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/"]}]},{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/#primaryimage","url":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/hp-kopie.png","contentUrl":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/09\/hp-kopie.png","width":650,"height":138},{"@type":"BreadcrumbList","@id":"https:\/\/www.jstconsultancy.cz\/en\/metalco-and-astm-e3499-25\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.jstconsultancy.cz\/"},{"@type":"ListItem","position":2,"name":"Metalco and ASTM E3499-25"}]},{"@type":"WebSite","@id":"https:\/\/www.jstconsultancy.cz\/#website","url":"https:\/\/www.jstconsultancy.cz\/","name":"JST Consultancy","description":"Tepeln\u00e9 zpracov\u00e1n\u00ed kov\u016f, expertn\u00ed \u010dinnost, ekonomick\u00e9 anal\u00fdzy kal\u00edren, \u0161kolen\u00ed tepeln\u00e9ho zpracov\u00e1n\u00ed","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.jstconsultancy.cz\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"cs"},{"@type":"Person","@id":"https:\/\/www.jstconsultancy.cz\/#\/schema\/person\/7edfc0603f64b2f7bc0ba172e703fc76","name":"Ji\u0159\u00ed Stanislav"}]}},"_links":{"self":[{"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/posts\/14790","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/comments?post=14790"}],"version-history":[{"count":1,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/posts\/14790\/revisions"}],"predecessor-version":[{"id":14793,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/posts\/14790\/revisions\/14793"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/media\/14746"}],"wp:attachment":[{"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/media?parent=14790"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/categories?post=14790"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/tags?post=14790"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}