{"id":14723,"date":"2026-08-31T19:07:32","date_gmt":"2026-08-31T19:07:32","guid":{"rendered":"https:\/\/www.jstconsultancy.cz\/?p=14723"},"modified":"2026-08-31T19:25:13","modified_gmt":"2026-08-31T19:25:13","slug":"giga-tools-and-tempering","status":"publish","type":"post","link":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/","title":{"rendered":"GIGA tools and tempering"},"content":{"rendered":"<p>A lot has already been explained about hardening furnaces. But what about tempering? To give you an idea, there are a few certainties in our forecasts.<\/p>\n<ul>\n<li>There will always be only one part in the furnace, <strong>weighing several tons<\/strong><\/li>\n<li>There will always be at least <strong>3 temperings<\/strong>, maybe even more<\/li>\n<li>Even though <strong>Nadca-207<\/strong> says that tempering in air is possible, I have been trying to completely rule out this idea for a long time. A protective atmosphere must always be applied. Only if we have allowances larger than 0.5 mm on the entire part, which we machine from all sides of the shaped part after hardening and tempering, i.e. from non-functional surfaces, can we use air. The basis is <strong>AMS 2759<\/strong> and their definition of surface types <strong>Type 1 to 4<\/strong>, and the classification of atmospheres into<strong> A, B and C<\/strong>. If you don&#8217;t believe it, it will be too late when you find out. I already have the experience. In addition, it is necessary to consider that we will carry out annealing <strong>after EDM, after welding, after testing,<\/strong> where the entire working cavity or part of it is already free of machining allowances<\/li>\n<li>The temperature of the part must be controlled by a thermocouple in the <strong>Tc core<\/strong>, as is common for this type of processing according to <strong>Nadca-207<\/strong>. Otherwise, we cannot ensure repeatable hardness values<\/li>\n<li>The furnace class according to <strong>Nadca-207<\/strong> is prescribed at <strong>+\/-14\u00b0C.<\/strong> However, since there is also a reference to <strong>CQI-9<\/strong>, in <strong>Process Table A<\/strong>, <strong>point A2.4<\/strong>, <strong>+\/-10\u00b0C<\/strong> is specified here. Since neither of these standards is prepared for <strong>GIGA<\/strong> dies, it must be said that <strong>+\/- 5\u00b0C<\/strong> is my recommendation. And why <strong>+\/-5\u00b0C<\/strong>? There is something like the <strong>Hollomon-Jaffe parameter<\/strong>, which quantifies the influence of tempering temperature and time according to the formula: <strong>P = T*(C+log10 t)<\/strong>. If the tempering temperature is <strong>570 \u00b0C<\/strong> and the time is <strong>2 hours<\/strong>, then <strong>P<sub>565<\/sub>\u200b=15*(20+log<sub>10<\/sub>\u200b2)<\/strong> and the time <strong>t<sub>ekv<\/sub> = 1.52 h<\/strong>. This number tells us that tempering for <strong>2 h at 565 \u00b0C<\/strong> has approximately the same tempering effect as <strong>1.52 h<\/strong> at <strong>570 \u00b0C<\/strong>. The hottest spot will be <strong>570+5\u00b0C<\/strong> with <strong>t<sub>ekv<\/sub> = 2.64 h<\/strong>. The difference is almost double, at <strong>+\/-10\u00b0C<\/strong> it is three times and at <strong>+\/14\u00b0C<\/strong> it is more than four times.<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-14712\" src=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-300x225.png\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-300x225.png 300w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-1024x768.png 1024w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-768x576.png 768w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-195x146.png 195w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-50x38.png 50w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-100x75.png 100w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-960x720.png 960w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-250x188.png 250w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51-500x375.png 500w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-10_33_51.png 1448w\" sizes=\"auto, (max-width:767px) 300px, 300px\" \/><\/a><\/p>\n<ul>\n<li>If we use multiple batch thermocouples, and I see this as almost a necessity, the 2-hour tempering time will start when the coldest thermocouple reaches the lower limit of the temperature field tolerance, <strong>T<sub>load,min<\/sub>\u2265T<sub>SP<\/sub>\u200b\u2212\u0394T<sub>uniformity\u200b<\/sub><\/strong>. This also corresponds to aviation standards such as <strong>AMS 2774, AMS 2759\/D, AMS 2801<\/strong>, etc. For furnace class 5 it will be <strong>-14\u00b0C<\/strong>, for furnace class 4 <strong>-10\u00b0C<\/strong> and for furnace class 2 <strong>-5\u00b0C<\/strong>.<\/li>\n<li>When cooling after tempering, it is necessary to take into account that during slow cooling, prolonged stay of the part at <strong>temperatures of 550 to 350\u00b0C<\/strong> can cause internal structural changes leading to a decrease in toughness. This is mainly the precipitation of <strong>Cr, Mo, V carbides,<\/strong> along with their coarsening and coalescence. At the same time, <strong>high Si and P<\/strong> contents can cause temper embrittlement. Steels with higher <strong>Si<\/strong> content (<strong>H11<\/strong>) will be more susceptible to this embrittlement than modern steels with <strong>lower Si<\/strong> content (<strong>Daido-GIGA, MT1, Dievar<\/strong>) [1]. The cooling rate after tempering is not defined anywhere, but it should be as high as possible, both for the reasons mentioned above and also for the economy of cooling parts weighing several tons<\/li>\n<li>The end tempering cooling temperature must always be <strong>Ts= 50 C.<\/strong><\/li>\n<li>As with quenching, a <strong>square chamber<\/strong> will be more efficient than a round chamber<\/li>\n<li>If we temper in air, we must work only with an atmospheric pressure of <strong>1 bar abs.<\/strong><\/li>\n<li>If we temper in a retort furnace, we usually have an overpressure of only a <strong>few mbar,<\/strong> and in addition, I have to heat and cool a retort weighing hundreds of kg with each cycle<\/li>\n<li>If we temper in a vacuum furnace, we usually have the option of <strong>up to 1.5 bar abs.<\/strong> This overpressure is usually tied to the design of the furnace door. However, an overpressure of <strong>0.5 bar<\/strong> will not be sufficient for effective cooling of such massive parts after tempering<\/li>\n<li>If we deal with the design and closure of the door, we can go to higher pressures, e.g. <strong>3 bar abs<\/strong>. Both during convection heating and cooling. And what is the difference? At a pressure of 1 bar abs. we will have a heat transfer of approximately 30 W\/m<sup>2<\/sup>K, at 3 bar then twice as much, 60 W\/m<sup>2<\/sup>K.\u00a0 For one tempering cycle for the reference block, we will save up to 15 hours of time. With triple tempering, it is 45 hours, almost 2 days.<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-14714\" src=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-300x225.png\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-300x225.png 300w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-1024x768.png 1024w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-768x576.png 768w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-195x146.png 195w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-50x38.png 50w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-100x75.png 100w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-960x720.png 960w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-250x188.png 250w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26-500x375.png 500w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_52_26.png 1448w\" sizes=\"auto, (max-width:767px) 300px, 300px\" \/><\/a><\/p>\n<ul>\n<li>During rapid convection heating, it is necessary to control the difference <strong>Ts\u2212Tc,<\/strong> because it creates transient thermal stresses. The infographic shows that during heating, even at <strong>1 bar abs<\/strong>. we can exceed the recommended difference <strong>dT = Ts-Tc \u2264110 C<\/strong> according to <strong>Nadca 207<\/strong>. So even if the part did not crack during hardening, it can happen during tempering. And not only because of <strong>dT<\/strong>, but also because of the simultaneous t<strong>ransformation of austenite to martensite<\/strong>. So for heating, I would be very careful with increasing the pressure, for cooling it makes sense both economically and metallurgically.<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-14716\" src=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-300x225.png\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-300x225.png 300w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-1024x768.png 1024w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-768x576.png 768w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-195x146.png 195w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-50x38.png 50w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-100x75.png 100w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-960x720.png 960w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-250x188.png 250w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44-500x375.png 500w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-27.-8.-2026-23_29_44.png 1448w\" sizes=\"auto, (max-width:767px) 300px, 300px\" \/><\/a><\/p>\n<ul>\n<li>But can we go even higher with the overpressure during tempering? The following figure shows the case where we increase the pressure to <strong>5 bar abs<\/strong>. Surprisingly, we will get into a situation where the efficiency of this step will have a lower impact. If we increase the pressure during tempering from <strong>1 to 3 bar abs.<\/strong>, the cooling efficiency will <strong>increase by 45%<\/strong>, while if we increase it from <strong>3 bar to 5 bar<\/strong> abs. then only by<strong> 20-30%.<\/strong> However, the demands on the pressure vessel, the performance of the cooling fan, and a larger heat exchanger will increase. <strong>3 bar abs. therefore seems to be a good compromise.<\/strong><\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-14718\" src=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-300x225.png\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-300x225.png 300w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-1024x768.png 1024w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-768x576.png 768w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-195x146.png 195w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-50x38.png 50w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-100x75.png 100w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-960x720.png 960w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-250x188.png 250w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01-500x375.png 500w, https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/ChatGPT-Image-31.-8.-2026-11_13_01.png 1448w\" sizes=\"auto, (max-width:767px) 300px, 300px\" \/><\/a><\/p>\n<p>What to say in conclusion? In single-chamber vacuum furnaces, solutions designed for tool hardening or for aerospace applications prevail. It is surprising when the tempering operation is as important as hardening.<\/p>\n<p>Many will argue that I can temper in this way <strong>in a hardening furnace<\/strong>. In terms of overpressure during cooling, I have much greater options. Yes, I do. But the hardening furnace is designed for hardening, i.e. high temperatures, and we are operating in the range of low temperatures to which the hardening furnace is not fully adapted. The second objection is economics. As can be seen from the analysis, the tempering cycle times are almost <strong>24 hours or more,<\/strong> and I cannot harden during this period. And since I need to temper <strong>at least 3 times,<\/strong> the purpose of the hardening furnace, the most expensive link in the entire chain, will not be used. The processing prices will be disproportionately high, as the hourly costs of a quenching furnace will be significantly higher than for a tempering furnace, usually up to 3 times.<\/p>\n<p>Do you agree with what I have said? You don&#8217;t have to, but it is gratifying that <strong>TAV Vacuum Furnaces<\/strong> is already able to supply such a furnace.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p>[1] <em>Mesquita, Rafael Agnelli; Barbosa, Celso Antonio; Kestenbach, Hans-J\u00fcrgen; Gon\u00e7alves, Cristiane Sales.\u00a0<strong>EFEITO DO Si E P NA TENACIDADE DO A\u00c7O H11, UTILIZADO EM FERRAMENTAS DE TRABALHO A QUENTE<\/strong>, p. 2768-2777. In:\u00a061\u00ba Congresso Anual da ABM, Rio de Janeiro, 2006, ISSN: 2594-5327, DOI 10.5151\/2594-5327-2005-14508-0311<\/em><\/p>\n<p>=======================================================================================================<br \/>\n<strong>Are you solving a similar problem? I will help you with the analysis\u2026<\/strong><br \/>\n<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"&#x2714;\" \/>\u00a040+ years of experience in the field<br \/>\n<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"&#x2714;\" \/>\u00a030+ years of experience\u2026 HT-PROGRES, Bodycote, Galvamet<br \/>\n<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"&#x2714;\" \/>\u00a0cooperation\u2026 V\u0160B, Czechimplant, ECM Technologies, TAV Vacuum Furnaces, GHC Invest<br \/>\n<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"&#x2714;\" \/>\u00a012+ years of expert activity<br \/>\nWant to ask for a solution or want a non-binding consultation? Click on this link, I will usually respond within 24 hours.\u00a0<a href=\"mailto:stanislav.jirka@gmail.com\">Contact email<\/a><br \/>\n========================================================================================================<br \/>\n<strong>Ji\u0159\u00ed Stanislav, Ing. CSc.<br \/>\n<\/strong>Consultant and forensic expert<br \/>\n========================================================================================================<\/p>\n<p>31\/8\/2026<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A lot has already been explained about hardening furnaces. But what about tempering? To give you an idea, there are a few certainties in our forecasts&#8230;.<\/p>\n","protected":false},"author":12,"featured_media":14721,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[322,332],"tags":[],"class_list":["post-14723","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nadca-207-en","category-tav-furnaces-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>GIGA tools and tempering - JST Consultancy<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/\" \/>\n<meta property=\"og:locale\" content=\"cs_CZ\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GIGA tools and tempering - JST Consultancy\" \/>\n<meta property=\"og:description\" content=\"A lot has already been explained about hardening furnaces. But what about tempering? To give you an idea, there are a few certainties in our forecasts....\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/\" \/>\n<meta property=\"og:site_name\" content=\"JST Consultancy\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-31T19:07:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-31T19:25:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"650\" \/>\n\t<meta property=\"og:image:height\" content=\"682\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ji\u0159\u00ed Stanislav\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Napsal(a)\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ji\u0159\u00ed Stanislav\" \/>\n\t<meta name=\"twitter:label2\" content=\"Odhadovan\u00e1 doba \u010dten\u00ed\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/\"},\"author\":{\"name\":\"Ji\u0159\u00ed Stanislav\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#\\\/schema\\\/person\\\/7edfc0603f64b2f7bc0ba172e703fc76\"},\"headline\":\"GIGA tools and tempering\",\"datePublished\":\"2026-08-31T19:07:32+00:00\",\"dateModified\":\"2026-08-31T19:25:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/\"},\"wordCount\":1290,\"image\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png\",\"articleSection\":[\"Nadca 207\",\"TAV Furnaces\"],\"inLanguage\":\"cs\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/\",\"url\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/\",\"name\":\"GIGA tools and tempering - JST Consultancy\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png\",\"datePublished\":\"2026-08-31T19:07:32+00:00\",\"dateModified\":\"2026-08-31T19:25:13+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#\\\/schema\\\/person\\\/7edfc0603f64b2f7bc0ba172e703fc76\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/#breadcrumb\"},\"inLanguage\":\"cs\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png\",\"contentUrl\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png\",\"width\":650,\"height\":682},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/en\\\/giga-tools-and-tempering\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"GIGA tools and tempering\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#website\",\"url\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/\",\"name\":\"JST Consultancy\",\"description\":\"Tepeln\u00e9 zpracov\u00e1n\u00ed kov\u016f, expertn\u00ed \u010dinnost, ekonomick\u00e9 anal\u00fdzy kal\u00edren, \u0161kolen\u00ed tepeln\u00e9ho zpracov\u00e1n\u00ed\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"cs\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.jstconsultancy.cz\\\/#\\\/schema\\\/person\\\/7edfc0603f64b2f7bc0ba172e703fc76\",\"name\":\"Ji\u0159\u00ed Stanislav\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"GIGA tools and tempering - JST Consultancy","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/","og_locale":"cs_CZ","og_type":"article","og_title":"GIGA tools and tempering - JST Consultancy","og_description":"A lot has already been explained about hardening furnaces. But what about tempering? To give you an idea, there are a few certainties in our forecasts....","og_url":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/","og_site_name":"JST Consultancy","article_published_time":"2026-08-31T19:07:32+00:00","article_modified_time":"2026-08-31T19:25:13+00:00","og_image":[{"width":650,"height":682,"url":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png","type":"image\/png"}],"author":"Ji\u0159\u00ed Stanislav","twitter_card":"summary_large_image","twitter_misc":{"Napsal(a)":"Ji\u0159\u00ed Stanislav","Odhadovan\u00e1 doba \u010dten\u00ed":"6 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/#article","isPartOf":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/"},"author":{"name":"Ji\u0159\u00ed Stanislav","@id":"https:\/\/www.jstconsultancy.cz\/#\/schema\/person\/7edfc0603f64b2f7bc0ba172e703fc76"},"headline":"GIGA tools and tempering","datePublished":"2026-08-31T19:07:32+00:00","dateModified":"2026-08-31T19:25:13+00:00","mainEntityOfPage":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/"},"wordCount":1290,"image":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png","articleSection":["Nadca 207","TAV Furnaces"],"inLanguage":"cs"},{"@type":"WebPage","@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/","url":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/","name":"GIGA tools and tempering - JST Consultancy","isPartOf":{"@id":"https:\/\/www.jstconsultancy.cz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/#primaryimage"},"image":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png","datePublished":"2026-08-31T19:07:32+00:00","dateModified":"2026-08-31T19:25:13+00:00","author":{"@id":"https:\/\/www.jstconsultancy.cz\/#\/schema\/person\/7edfc0603f64b2f7bc0ba172e703fc76"},"breadcrumb":{"@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/#breadcrumb"},"inLanguage":"cs","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/"]}]},{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/#primaryimage","url":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png","contentUrl":"https:\/\/www.jstconsultancy.cz\/wp-content\/uploads\/2026\/08\/Snimek-obrazovky-2026-08-25-164407-kopie-1.png","width":650,"height":682},{"@type":"BreadcrumbList","@id":"https:\/\/www.jstconsultancy.cz\/en\/giga-tools-and-tempering\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.jstconsultancy.cz\/"},{"@type":"ListItem","position":2,"name":"GIGA tools and tempering"}]},{"@type":"WebSite","@id":"https:\/\/www.jstconsultancy.cz\/#website","url":"https:\/\/www.jstconsultancy.cz\/","name":"JST Consultancy","description":"Tepeln\u00e9 zpracov\u00e1n\u00ed kov\u016f, expertn\u00ed \u010dinnost, ekonomick\u00e9 anal\u00fdzy kal\u00edren, \u0161kolen\u00ed tepeln\u00e9ho zpracov\u00e1n\u00ed","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.jstconsultancy.cz\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"cs"},{"@type":"Person","@id":"https:\/\/www.jstconsultancy.cz\/#\/schema\/person\/7edfc0603f64b2f7bc0ba172e703fc76","name":"Ji\u0159\u00ed Stanislav"}]}},"_links":{"self":[{"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/posts\/14723","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/comments?post=14723"}],"version-history":[{"count":1,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/posts\/14723\/revisions"}],"predecessor-version":[{"id":14724,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/posts\/14723\/revisions\/14724"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/media\/14721"}],"wp:attachment":[{"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/media?parent=14723"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/categories?post=14723"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jstconsultancy.cz\/wp-json\/wp\/v2\/tags?post=14723"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}